(1)Zoning environmental sanitation management
1)Dirty/Contaminated area
a.For surrounding environment,floor,and surface of the patient belongings,use 2,000 mg/L chlorine containing disinfectant(effect lasts>30 minutes),soak,spray or scrub,effect last>30 minutes,at least 4 times/d,increased if necessary.
b.For office supplies,per shift disinfect or wipe with disinfectant wipes(75%alcohol or 1,000 mg/L with chlorine)on the surface of medical personnel office desks and computers,at least 4 times/d.
c.For medical waste,clean up medical waste in ward at least 2 times/d.
2)Outside the dirty area
a.Overall requirements:maintain hygiene and tidiness,clean the surrounding environment at least 2 times/d;
b.Excreta,vomit,and secretions from patients:①The excreta shall be routinely dumped; ②If the floor is contaminated with blood,vomit,excreta,etc.,put an 2,000 mg/L chlorinecontaining disinfectant on the contaminated floor,then clean with mop; soak mop with 500 mg/L of chlorine disinfectant for 30 minutes,clean and dry.
c.Medical waste and waste from patients:use double-layered yellow garbage bags,close the bag.Clean up and dispose wastes at least once a day.
3)Buffer room
a.Floor:spray or wipe the floor with 500 mg/L chlorine-containing disinfectant at least 2 times per day.
b.Surface:wipe surface of desk with 500 mg/L chlorine disinfectant or disinfecting wipes(75% alcohol or 500 mg/L chlorine)at least 2 times/d.
c.Medical waste:clean up medical waste around exit of the buffer room from medical staff 4 times/d,with recommended time around 7:00,11:00,17:00,and 23:00.(https://www.daowen.com)
d.As there is no air circulation in the buffer room,and a plasma air sterilizer is needed for air disinfection.
4)Area for donning protective equipment
a.General requirements:maintain the area clean,and organize the overall environment and items every shift.
b.Floor:disinfect the floor using 500 mg/L chlorine containing disinfectant spray on the ground or use disinfectant wipe at least 2 times/d.
c.Air:after the medical staff change the protective equipment,open the windows and doors for ventilation,for 30 minutes each time.
5)Locker room
a.General requirements:maintain hygiene and tidiness,and clean the area at least 2 times/d.
b.Floor:spray with 500 mg/L chlorine disinfectant on the ground or with disinfectant wipe at least twice a day.
c.Eating:Regular eating in the locker room is prohibited.
6)Terminal disinfection
a.Disinfect surface of environment/floor/items:in the absence of obvious dirt or contaminants,spray or wipe the surface and floor with chlorine-containing disinfectant at concentration of 1,000 mg/L.When there are obvious contaminants or dirt,cover whole surface or floor with disposable absorbent material,spray to wet or soak with 5,000~10,000 mg/L chlorine-containing disinfectant for 30 minutes,and remove absorbent material.
b.Air clean and disinfect:disinfectants such as 3% hydrogen peroxide,0.2% acetic acid peroxide or 500 mg/L chlorine dioxide can be used.Aerosol sprays,at concentration of 10-20 ml/m3(1 g/m3),can be used.After 60 minutes of disinfection,exchange air with ventilation.Alternatively,heat fumigation with 15% acetic acid peroxide can be used,at concentration of 7 ml/m3.After 1-2 hours of heat fumigation,exchange air with ventilation.Attention shall be paid to the height of the exhibition center and stadium with large air space,and choose the high-pressure aerosol spray equipment with the required spray range for large air space disinfection.