参考文献:
[1]Merchant RM,Topjian AA,Panchal AR,et al.Part 1:Executive summary:2020 american heart association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care[J].Circulation,2020,142(16 suppl-2):S337-S357.
[2]Rajan S,Folke F,Hansen S M,et al.Incidence and survival outcome according to heart rhythm during resuscitation attempt in out-of-hospital cardiac arrest patients with presumed cardiac etiology[J].Resuscitation,2017,114:157-163.
[3]Huang Y,Wen X,Wang J,et al.Toward miniaturization of defibrillators:design of a defibrillation charge/discharge circuit[J].Conf Proc IEEE Eng Med Biol Soc,2019,2019:6155-6158.
[4]徐津申.自动体外除颤仪在急诊心搏骤停患者救治中的应用[J].医疗装备,2019,32(2):29-30.
[5]Okamura H,Desimone C V,Killu A M,et al.Evaluation of a unique defibrillation unit with dualvector biphasic waveform capabilities:towards a miniaturized defibrillator[J].Pacing Clin Electrophysiol,2017,40(2):108-114.
[6]武军元,李春盛,袁伟.猪经胸阻抗大小对除颤有效性和安全性的影响[J].中华急诊医学杂志,2017,26(3):308-312.
[7]Botto GL,Politi A,Bonini W,et al.External cardioversion of a trial fibrillation:role of paddle position on technical efficacy and energy requirements[J].Heart,1999,82(6):726-730.
[8]Kirchhof P,Eckardt L,Loh P,et al.Anterior-posterior versus anterior-lateral electrode positions for external cardioversion of atrial fibrillation:a randomised trial[J].Lancet,2002,360(9342):1275-1279.
[9]Cheskes S,Hillier M,Byers A,et al.The association between manual mode defibrillation,pre-shock pause duration and appropriate shock delivery when employed by basic life support paramedics during out-of-hospital cardiac arrest[J].Resuscitation,2015,90:61-66.
[10]Dalzell GW,Cunningham SR,Anderson J,et al.Electrode pad sizetransthoracic impedance and success of external ventricular defibrillation[J].Am Cardiol,1989,64(12):741-744.
[11]Bircher NG,Chan PS,Xu Y,et al.Delays in cardiopulmonary resuscitation,defibrillation,and epinephrine administration All decrease survival in in-hospital cardiac arrest[J].Anesthesiology,2019,130(3):414-422.(https://www.daowen.com)
[12]Lerman BB,Deale OC.Relation between transcardiac and transthoracic current during defibrillation in humans[J].Circ Res,1990,67(6):1420-1426.
[13]Coult J,Kwok H,Sherman L,et al.Ventricular fibrillation waveform measures combined with prior shock outcome predict defibrillation success during cardiopulmonary resuscitation[J].J Electrocardiol,2018,51(1):99-106.
[14]Coult J,Blackwood J,sherman L,et al.Ventricular fibrillation wave form analysis during chest compressions to predict survival from cardiac arrest[J].Circ Arrhythm Electrophysiol,2019,12(1):e006924.
[15]万智,唐万春.2015心肺复苏指南展望[J].中华急诊医学杂志,2011,20(1):7-10.
[16]Cay S,Ozcan F,Ozeke O,et al.Defibrillation failure:Considerations[J].J Arrhythm,2018,4(3):333-334.
[17]Kuschner C E,Becker L B.Recent advances in personalizing cardiac arrest resuscitation.F1000Res,2019,8:F1000 Faculty Rev-915.
[18]Schuger C.Is the best(waveform)the enemy of the good(waveform)A defibrillation challenge.JACC Clin Electrophysiol,2019,5(7):863-864.
[19]Shanmugasundaram M,Lotun K.Refractory out of hospital cardiac arrest[J].Curr Cardiol Rev,2018,14(2):109-114.
[20]Nichol G,Sayre M R,Guerra F,et al.Defibrillation for ventricular fibrillation:a shocking update.J Am Coll Cardiol,2017,70(12):1496-1509.
[21]Simon E M,Tanaka K.Double sequential defibrillation[J].Cardiol Clin,2018,36(3):387-393.
[22]Aiello S,Perez M,Cogan C,et al.Real-time ventricular fibrillation amplitude-spectral area analysis to guide timing of shock delivery improves defibrillation efficacy during cardiopulmonary resuscitation in swine.J Am Heart Assoc,2017,6(11):e006749.